AP 11 - Panel meter

ap11.jpg
  • Basic price:
    from 148 
    (Price without tax)
  •  

    Contact us for determination your price

You must set all configuration steps to add item in the cart. You can't skip any step.

1Input Select Input
Need advice, call us!
+420 493 504 261

11 universal with galvanic separ 25 EUR
Select
12 2x universal with galvanic separ 75 EUR
Select
21 Pt100 0 EUR
Select
22 2x Pt100 15 EUR
Select
23 Pt1000 0 EUR
Select
24 Ni1000/6180 ppm 0 EUR
Select
25 Ni1000/5000 ppm 0 EUR
Select
26 resistance transmitter 0 EUR
Select
27 2x Pt1000 15 EUR
Select
28 2x Ni1000/6180 ppm 15 EUR
Select
29 2x Ni1000/5000 ppm 15 EUR
Select
31 2 x current 0/4 – 20 mA 6 EUR
Select
32 2 x voltage 0-10 V 6 EUR
Select
33 1 x current 0/4 – 20 mA, 1 x voltage 0-10 V 6 EUR
Select
34 4 x current 0/4 – 20 mA 28 EUR
Select
35 4 x voltage 0-10 V 28 EUR
Select
36 2 x current 0/4 – 20 mA, 4x voltage 0-10 V 28 EUR
Select
37 counter; 1 x current signal input 0/4 - 20 mA; 1 x pulse signal input ** color display only 12 EUR
Select
38 integrator, 1 x current 0/4 – 20 mA; 1 x voltage 0/2 - 10 V **color display only 12 EUR
Select

2Contact output Select Contact output
Need advice, call us!
+420 493 504 261

0 empty 0 EUR
Select
1 2 x relay (switching contacts 250 VAC, 2A) 13 EUR
Select
2 4 x relay (switching contacts 250 VAC, 2A) 28 EUR
Select

3Analogue output Select Analogue output
Need advice, call us!
+420 493 504 261

0 empty 0 EUR
Select
1 current/voltage without galvanic separ 19 EUR
Select
2 current/voltage with galvanic separ. GS 32 EUR
Select

4Communication Select Communication
Need advice, call us!
+420 493 504 261

0 empty 0 EUR
Select
1 RS 232 * not with input 12 14 EUR
Select
2 RS 485 without GS 14 EUR
Select
3 RS 485 with GS 32 EUR
Select
4 2x RS485 without GS * not with input 12 24 EUR
Select
5 RS485 with GS + RS485 without GS * not with input 12 37 EUR
Select
6 RS485 with GS + RS232 * not with input 12 37 EUR
Select

5Power supply Select Power supply
Need advice, call us!
+420 493 504 261

1 80 až 253 V AC 0 EUR
Select
2 18 až 36 V AC/DC 0 EUR
Select

6Display Select Display
Need advice, call us!
+420 493 504 261

1 red 0 EUR
Select
2 green 0 EUR
Select
3 yellow 0 EUR
Select
4 three colour 20 EUR
Select

7Software Select Software
Need advice, call us!
+420 493 504 261

001 standard 0 EUR
Select
004 Counter (only with input 37)** 0 EUR
Select
005 integrator (only with input 38)** 0 EUR
Select
XXX special requirement - consult by phone 0 EUR
Select

Panelmeter AP 11 is 5 digit programmable apparatus for universal use. Apparatus is controlled with digital
signal processor with A/D transducer. Panelmeter is operated with key-board placed on front panel or with
control software that is used for setting of all parameters and archiving measured values. Panelmeter has
to be provided with communication line, variants of communication lines are in ordering code. Control
software is included in standard delivery. Panelmeter is equipped with three-colour display allowing for a
quick check of limits within measured value oscillates. Visually interesting element is auxiliary horizontal
barograph. Offer of input signals includes resistance temperature sensors (Pt100, Pt1000, Ni1000/6180ppm,
Ni1000/5000ppm), thermocouple (J, K, E, T, R, S, B) and unified outputs from sensors of technological processes
(4-20 mA, 0-20 mA, 0-10 V). Type of panelmeter with universal input with galvanic separation is also
available. In this case necessary type of input signal is simply configured from keyboard during installation
of panelmeter into technological equipment. Advantages of this type is higher accuracy, galvanic separation
of input signal and universal use and thus minimizing number of spare pieces to ensure uninterrupted operation.
Type AP11 is produced also in modification with more inputs, particularly in following modifications:
2x Pt100; 2x current signal 0(4)-20 mA, 1x current signal 0(4)-20 mA + 1x voltage signal 0-10 V; 4x current
signal 0(4)-20 mA; 4x voltage signal; 2x current signal 0(4)-20 mA + 2x current signal 0-10 V. Power source
with load capability 100 mA, that can feed current loops of passive sensors, is built in panelmeter. It can
also be equipped with two or four limit switches whose outputs are relay switching contacts. Functions of
switches on multi-input panelmeter types is programmable. E.g. any limit switch (or more switches) can be
assigned to any input. Limit switches can be compared also with value of sum or difference of two inputs.
Desired value is set individually for each limit switch or together for all limit switches when any deviation
from common desired value can be set for each limit switch. Hysteresis and reaction of output relay on
achieving of desired value can be set on each switch individually. Limit switches can be set also for safety
function. Then the switch after its connecting has to be deactivated. There is an variant with analogue output
that can be galvanic separated in panelmeter ordering code.
With multi-stage types of panelmeters analogue output can be assigned to any input by a program, eventually
to sum or difference of two inputs. Any of the communication line variants can be used for communication
of panelmeter with PC.
Communication lines RS232 or RS485 (can be galvanic separated) are in ordering code. Two communication
lines RS485 (one can be galvanic separated) or combination of two communication lines RS232 and RS485
can be used for above standard applications. Communication enables not only setting of parameters and
data archiving, but regarding the possibility of addressing of individual panelmeters it can be also used for
interconnection of bigger number of apparatuses and controlling of complete technological lines. Apparatus
features offers large possibilities of its usage, not only for simple rendering of measured signals but also as
signal transducers, galvanic separation, data collection for their processing on PC, as limit switches, simple
two-state regulator, apparatuses for failure signalling or as mathematical units.